Multichannel analyzer for parallel counting AMP-12 "Puls-1A"
Multichannel analyzer for parallel counting AMP-12 "Pulse-1A" (the analyzer) is a major structural element of the automated radiation monitoring system (ARMS) of NPPs. The analyzer is designed to create a new system or upgrade existing AKRB-03, 06,08 and their analogues.
The analyzer is intended for simultaneous reception of multiple channels of pulsesignals from the detection blocks and devices of ionizing radiation in the form of a sequence of statistically distributed pulses and measuring the counting rate of pulses; the simultaneous reception of multiple channels of analog signals the DC and voltagefrom the sensor with standardized output signals and convert them to physical quantities for each measuring channel.
- The analyzer is used in measuring information systems of radiation control for normal operating conditions on NPPs.
- The analyzer is a means of measuring equipment in accordance with GOST 27452-87 and refers to the technical means of measuring information systems of radiation control for normal operating conditions on NPPs.
- The analyzer refers to the technical means of automation of normal operation information systems.
- To influence the NPP safety analyzer is classified as normal operation.
Analyzer AMP-12 "Pulse-1A" passed state acceptance tests on DSTU 3400-2000, has a certificate of type approval № UA-MI/1-1437-2004 issued by the State Committee of Ukraine for technical regulation and consumer policy and submitted to the State Register of measuring instruments under the number U1807-03. TU U 33.2-19130157-009-203 consistent with the State Nuclear Regulatory Committee of Ukraine.
| Range of measuring the counting rate of pulses, s-1 | from 0,01 to 6×104 |
| The frequency range of registration the input pulses, Hz |
from 1×10-2 to 6×104 |
| Pulse amplitude, V |
from 3 to 12 |
| Pulse duration, µs |
from 0,2 to 2,5 (at least 50% of pulse amplitude) |
| The polarity of the pulse |
positive |
| The number of channels for receiving the pulse signals |
not more 60 |
| DC current, mA |
from 0,05 to 20 |
| The range of measuring DC voltage, V |
from 0,1 to 10 |
| Number of input DC voltage and current |
not more 60 |
| The instability of readings,% |
not more 0,5 |
| Time of continuous work, hours per day |
24 |
| Operation mode setup time, min |
not more 2 |
| Measurement time, s: - when measuring the counting rate of pulses; - when measuring the DC voltage |
from 1 to 10000 not more 2 |
| Power consumption including the power consumed by connected to the the analyzerdetection units and devices, VA |
not more 950 |
Operating conditions
| The ambient air temperature, °C |
from +5 to +50 |
| Relative humidity,% – lasting impact at 50 °C; – short-term exposure at 20 °C (no condensation) |
75±3 95±3 |
| Atmospheric pressure, kPa |
from 54 to 540 |
- in the cabinet for wall mounting, which houses a set of analyzer;
- in the cabinet for wall mounting, that houses no more than two sets of analyzer;
- in the cabinet for floor mounting, that houses no more than three sets of blocks and units of the analyzer.