RKS-02 "Kordon"RZBA-04-04MAMP-12 "Puls 1A"MKS-2001Pump blocks
Radiometer RUG-2001BDMG-04RW systemRadon monitoringRadiation monitoring

Pump block BN-01

Pump block BN-01 with measuring device UDA-1AB

The block pump BN-01 with measuring devices UDA-1AB and UDG-1B

Main

News

About us

Production

Services

Projects

 

 

1. Destination
2. Composition of product
3. Specifications
4. Pump block at objects

To top
1. Destination
- The block has intended for the bleeding air through metering devices of settings UDA-1AB, UDG-1B and UDGB-01Т (production of scientific production enterprise "DOSA", Russia).  It is working in unison (pneumatic tandem connection of settings UDA-1AB, UDG-1B and the block).
- The block does controlled of a band filter dirtiness of a setting UDA-1AB and initiates change of a frame by band filter of a setting UDA-1AB.
- The block does controlled of a band filter integrity of a setting UDA-1AB and excites issue of an emergency signal by setting UDA-1AB at the damage of a band filter.
Sampling of air could be carry out as immediately from an atmosphere of industrial premises, and at the help isokinetic sonde from vent systems of Nuclear Power Plants (trier OS-1700 ("AMETЕК", USA)).
ADVANTAGES:
The block does ensuring constant air consumption through measuring gears and the settings. Value of an expense can be variated at the help adjusting parameters;
- The block does produced diagnostic of built-in devices;
- The block does triggered a pressure difference on the measuring devices and settings.
Pump blocks BN-01-02 and BN-01-03:
- had allowing to control temperature in a line of assay delivery to settings UDA-1AB and UDGГ-1B for non-admissionwith a moisture condensation on walls of the pipe duct;
- are equipped by two pompes working by a principle of "hot" reservation (at abandoning the basic pompe doing automatic change-over to the reserve);
- had ensuring the regulation of drawn air in dependence from an expenditure for environment of sampling;
- had realizing the monitoring of pressure difference on an analytical filter (measuring equipment), a diagnostics of built-in devices and a choronomic consumption indicator and a temperature detector.

To top


Pump block BN-01-01
 

UDA-1AB


UDG-1B


UDGB-01T

Pump block BN-01-01

 

Sampling and transfer air through measuring gears of  UDA-1AB,     UDG-1B, UDGB-01T.


Pump block BN-01-02
 

Pump block BN-01-02

Sampling and transfer air selected using isokinetic sonde, through measuring gears of equipments UDA-1AB and UDG-1B
which working in unison

To top


Pump block BN-01-03
 

OS-1700

Pump block BN-01-03

Sampling and transfer  air selected using isokinetic sonde, through a line of delivery tests, the analytical filter and a fixed trier of tritium OS-1700


To top
2. Composition of product
The pump block is at all its component parts.

Pump block with equipment UDA-1AB

Appearance of pump block BN-01-03 (with built-in  manifold of tritium OS 1700)

Pump block with equipment
UDA-1AB
Pump block with manifold of tritium OS-1700


Functional structure of the pump block:

  • The vacuum pump;

  • Unit of monitoring of pressure;

  • Indicator - regulator;

  • The frequency inverter;

  • The communications hub of control circuits;

  • The communications hub of supply circuit;

  • Cooler (fan FL-100).

The basic element of the pump block is a lamellar vacuum pump VT4.4
The pump is integrated with the three-phase induction motor with a capacity of 0,18 kw



To top
3. Specifications
 

The nominal productivity range of  the block from 0 to 73 l/min
The power supplies of the block are carried out from a single-phase net alternating-current a strain
and frequency

from  187 to 242 V

from 49 to 51 Hz

The power consumed by the block, no more 300 Watt
The pump block degree of protection P54 по ГОСТ14254.
Average time to failure of the block - not less 10000 h
Average endurance of the block - not less 10 years
Mean time re-enter of a up state - no more 1 h


 

Service conditions

Temperature from a plus 5 up to a plus 50 оС

The upper value of relative humidity of 80 % at 35 оС and lower temperatures without a moisture condensation
Atmospheric pressure from 84 up to 106,7 kPa


4. Pump block at objects
- Sanitary sluice of «Cover» object  GSP Chernobyl NPP  4 units since 2004;
- ННЦ «Institute of metrology», Kharkov  3 units since 2004
- HOIT-2 GSP Chernobyl NPP, Chernobyl 9 units since 2004 г.

To top

 



 

Main

News About us Production Services Projects