1.
Destination and structure
2.
Performance attributes
3. Ability
of analyzer
4.
AMP-12 "Puls 1A" at objects
To top
1.
Destination and structure
The analyzer has a module-block construction and is emitted in two
modifications:The
analyzer
АМП-12
"Puls 1A" was developed for reconstruction systems Radiation Control
(RC)
on ASKRS-03,
06, 08 basis. It could use in new systems RC
and as a self-contained means of automation.
The analyzer has intended for:
-
the
simultaneous reception on several ports the pulse signals how had acting
from detection units (DU) and sets of detection (SD) the ionizing radiations
as a sequence statistically the distributed pulses and measuring of a
counting rate of the pulses.
-
the simultaneous reception on several ports the direct-current analog
signals and a strain from sensors with unified output signals and their
count in physical quantities on each port of measuring.
- the analyzer has used
in measuring intelligence systems of RC for standard conditions of exploitation
on NPPs.
- the analyzer is a measuring instrument technique and has concerned to hardware
components of RC system NPPs.
- the analyzer has concerned hardware components of automation's (HСА)
intelligence systems of normal exploitation.
The analyzer has BBC construction and it has two alternatives:
|
1.
In a case for wiring on a
wall in which one package of blocks and units of the
evaluator is placed |
2. In a case for wiring on a floor in which it is
placed no more than three packages of blocks and units of
the evaluator |
 |
 |
 |
 |
| Housing
with convenient access to units |
Rear
of analyzer |
To top
2. Performance attributes
|
Range of measuring
a counting rate of pulses |
from 0,01
to
60000
s-1 |
|
Limens of a supposed basic
relative error
measuring of a counting rate pulses in percentage at
probability 0,95 (n - counting rate of pulses, s-1;
tmeasuring - time of measuring) |
± (0,5 + (100/(n • tmeasuring))) |
|
Performances
of entering pulse signals:
- A range of frequency filing of pulses
- Voltage of pulses
- Duration of pulses
- Polarity of pulses
- Quantity of channels for reception of pulse signals |
from
1×10-2 to 60000
Hz;
from 3
to 12 V
from 0,2
to 2,5 mcs up-to-date 0,5 from amplitude of pulses
positive
no more 60 |
|
Range of
direct-current measuring |
from
0,05
to 20
mA |
|
The range of
direct current measuring broken-down on two sub-bands: |
from 0,05 to 5
mA
from 0,2 to 20
mA |
|
Range of
measuring of a dc voltage |
from 0,1
to
10 V |
|
Limens of a supposed basic relative error of measuring of a
dc voltage in percentage at
confidence
probability 0,95 |
± [0,5+0,5(10/Umeasuring-1)] |
|
Quantity of
direct-current input signals and strains |
no more
60 |
|
Instability of indications |
no more
0,5 % |
|
Time of
continuous operation |
not less
24 h |
|
Stabilization time of an operating mode |
no more
2
min |
|
Time of
measuring, s:
- At measuring a counting rate of pulses
- At measuring a dc voltage |
from
1
to 10000
no more
2 |
|
The
power consumption with the connected DU and SD to evaluator
is. |
no more
950
V×A
|
Service conditions
|
Ambient
temperature, °С |
+5...+50 |
|
Relative
humidity:
– long-term exposure by 50 °С, %
– brief exposure by 20 °С (without moisture
condensation),% |
75±3
95±3 |
|
Atmosphere pressure,
kPascal |
54...540 |
Overall dimensions,
mm, no more:
|
Wall modification |
Floor
modification |
|
-
width -
600; |
- width -
670; |
|
-
height -
1012; |
- height-
2100; |
|
- depth -
515. |
-
depth
- 870. |
|
Weight - no
more 220 kg. |
To top
3.
Ability
of analyzer
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
It does provide the current supply from internal sources
on peripheral equipments the strains of the
direct-current supply "+ 6V", "+ 12V", "-12V", "+400V"
and "+550V";
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
It does provide of automatic restart at the command of
interface RS-485, and it is self-contained in the
following events:
- At a potential input of the current supply;
- At failures in-process of the analyzer;
- As a result of miss (with consequent renewal) the
current supply on both lines of mains voltage.
|
To top
4. AMP-12
"Puls 1A" at objects
- Enterprise «AtomSystemPribor»,
Obninsk, Russia, 4 units since 2004;
- «Rovno NPP» generating unit №3, 2 units since 2004 and 5
units since 2004;
- «Rovno NPP» generating unit №4, 7 units since 2004;
- ОП «Zaporozhye NPP» generating unit №1, 5 units
since 2004;
- Ignalina NPP, 1 unit since 2003 and 16 units since 2004.
|